Sciex 6600 TripleTof

TripleTof 6600 Quadrupole Time-of-Flight (QTOF) mass analyzer.

 

Instrument Manufacturer

Sciex

Instrument Model

6600 TripleTof

Product specifications

Company: Sciex
Instrument type: QTOF
Instrument system: MS (Mass Spectrometer)

We deliver each pre-owned system FOB. Installation is done on basis of the original specification of the instrument, hands-on training and warranty.
We will continue supporting the system after the warranty period, a.o. via a range of service contract options.

System features

Take on new analytical challenges and extend your research capability with the TripleTOF® 6600 Quadrupole Time-Of-Flight (QTOF) mass analyzer. The TripleTOF technology delivers high performance and reproducibility that can virtually detect any peptide. Ultra-fast acquisition rates allow you to collect high-resolution MS/MS data on every detectable analyte in your sample, giving you the potential you need to advance your research.

The TripleTOF 6600 System offers:

  • A broad dynamic range of greater than 5 orders of magnitude
  • Wide Q1 mass range with isolation for ions up to 2250 m/z
  • Scan speed of up to 100 Hz (100 MS/MS spectra per second)
  • MS/MS Resolution of equal or greater than 30,000 (FWHM)
  • The TripleTOF 6600 System maximizes productivity with its real-time management of MS/MS acquisition time, based on the intensity of selected precursors.
  • SWATH acquisition for label-free quantitation including variable window SWATH with up to 200 SWATH windows for optimal coverage of complex proteomics data

Detailed information

Specifications
Mass Range TOF 5 – 40,000 m/z
Mass Selection Range Q1 5 – 2250 m/z
TOF-MS Mass Resolution and Acquisition Speed ≥35,000 (FWHM) at 956 m/z, using 10 ms accumulation time
TOF-MS/MS Mass Resolution and Acquisition Speed ≥30,000 (FWHM) at 813 m/z, and ≥25,000 (FWHM) at 195 m/z, using 10 ms accumulation time
Detector Type 4-channel MCP detector with ADC signal processing for extended dynamic range
Flexible Data Acquisition Workflows TOF-MS
Information dependent acquisition (IDA) MS/MS
Data Independent SWATH® Acquisition with fixed or variable Q1 isolation windows
Targeted MRMHR workflow
Ionization Sources IonDrive™ Turbo V, DuoSpray™  source, each with TurboIonSpray® or Atmospheric-pressure chemical ionization (APCI) probes available; NanoSpray® III source, Digital PicoView NanoSource
Variable Window SWATH® Acquisition Data-Independent SWATH® Acquisition with variable window capabilities, allows for a large number of Q1 isolation windows at user controlled widths, up to 200 per cycle to achieve better specificity, even in complex samples. Read More
Data File Portability Condensed data file sizes simplify and streamline data storage and portability for sharing with colleagues, without losses in data quality, completeness or security

 

Category: Product specifications:   <p>Company: Sciex<br /> Instrument type: QTOF<br /> Instrument system: MS (Mass Spectrometer)</p> <p><span style="display: inline !important; float: none; background-color: #ffffff; color: #333333; cursor: text; font-family: Georgia,'Times New Roman','Bitstream Charter',Times,serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;">We deliver each pre-owned system FOB. Installation is done on basis of the original specification of the instrument, hands-on training and warranty. </span><br /> <span style="display: inline !important; float: none; background-color: #ffffff; color: #333333; cursor: text; font-family: Georgia,'Times New Roman','Bitstream Charter',Times,serif; font-size: 16px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;">We will continue supporting the system after the warranty period, a.o. via a range of service contract options.</span></p> System features:   <p>Take on new analytical challenges and extend your research capability with the TripleTOF® 6600 Quadrupole Time-Of-Flight (QTOF) mass analyzer. The TripleTOF technology delivers high performance and reproducibility that can virtually detect any peptide. Ultra-fast acquisition rates allow you to collect high-resolution MS/MS data on every detectable analyte in your sample, giving you the potential you need to advance your research.</p> <p>The TripleTOF 6600 System offers:</p> <ul> <li>A broad dynamic range of greater than 5 orders of magnitude</li> <li>Wide Q1 mass range with isolation for ions up to 2250 m/z</li> <li>Scan speed of up to 100 Hz (100 MS/MS spectra per second)</li> <li>MS/MS Resolution of equal or greater than 30,000 (FWHM)</li> <li>The TripleTOF 6600 System maximizes productivity with its real-time management of MS/MS acquisition time, based on the intensity of selected precursors.</li> <li>SWATH acquisition for label-free quantitation including variable window SWATH with up to 200 SWATH windows for optimal coverage of complex proteomics data</li> </ul> Detailed information:   <table width="623"> <thead> <tr> <td colspan="2" width="100%">Specifications</td> </tr> </thead> <tbody> <tr> <td width="57%">Mass Range TOF</td> <td width="42%">5 – 40,000 m/z</td> </tr> <tr> <td width="57%">Mass Selection Range Q1</td> <td width="42%">5 – 2250 m/z</td> </tr> <tr> <td width="57%">TOF-MS Mass Resolution and Acquisition Speed</td> <td width="42%">≥35,000 (FWHM) at 956 m/z, using 10 ms accumulation time</td> </tr> <tr> <td width="57%">TOF-MS/MS Mass Resolution and Acquisition Speed</td> <td width="42%">≥30,000 (FWHM) at 813 m/z, and ≥25,000 (FWHM) at 195 m/z, using 10 ms accumulation time</td> </tr> <tr> <td width="57%">Detector Type</td> <td width="42%">4-channel MCP detector with ADC signal processing for extended dynamic range</td> </tr> <tr> <td width="57%">Flexible Data Acquisition Workflows</td> <td width="42%">TOF-MS<br /> Information dependent acquisition (IDA) MS/MS<br /> Data Independent SWATH® Acquisition with fixed or variable Q1 isolation windows<br /> Targeted MRMHR workflow</td> </tr> <tr> <td width="57%">Ionization Sources</td> <td width="42%">IonDrive™ Turbo V, DuoSpray™  source, each with TurboIonSpray® or Atmospheric-pressure chemical ionization (APCI) probes available; NanoSpray® III source, Digital PicoView NanoSource</td> </tr> <tr> <td width="57%">Variable Window SWATH® Acquisition</td> <td width="42%">Data-Independent SWATH® Acquisition with variable window capabilities, allows for a large number of Q1 isolation windows at user controlled widths, up to 200 per cycle to achieve better specificity, even in complex samples.<a href="https://sciex.com/x59201.xml"> Read More</a></td> </tr> <tr> <td width="57%">Data File Portability</td> <td width="42%">Condensed data file sizes simplify and streamline data storage and portability for sharing with colleagues, without losses in data quality, completeness or security</td> </tr> </tbody> </table> <p> </p> Additional Information:   , Sciex, 6600 TripleTof, , ,