Waters Xevo TQ-S

We have a Waters Xevo TQ-S for sale. Instrument is in good condition. Contact us for details and pricing

Description / Model

TQ-S

Instrument Manufacturer

Waters

Product specifications

Company: Waters
Instrument type: Benchtop tandem quadrupole
Instrument system: MS (Mass Spectrometer)

System features

Xevo® TQ-S is an advanced benchtop tandem quadrupole mass spectrometer, designed to meet the needs of your most demanding quantitative LC-MS/MS applications.

Xevo TQ-S features revolutionary off-axis StepWave™ ion transfer optics that dramatically increases the efficiency of ion transfer from the ion source to the quadrupole MS analyzer at the same time as actively eliminating undesirable neutral contaminants.

Xevo TQ-S also features ScanWave™ collision cell technology to provide the very best high-speed MRM, an enhanced product ion spectral acquisition capability and a valuable, information-rich acquisition mode known as RADAR.™ The system incorporates IntelliStart™ Technology, for automated system optimization and status monitoring, ensuring that the highest quality data is routinely available to all levels of operator.

SYSTEM HARDWARE SPECIFICATIONS

API sources and ionization modes High performance ZSpray™ dual-orthogonal API sources:

  • Multi-mode source – ESI/APCI/ESCi®

Vacuum system

  • Three air-cooled turbomolecular vacuum pumps;
  • Two vacuum backing pumps

Dimensions

  • Width: 61.0 cm (24.0 in.)
  • Height: 70.7 cm (27.8 in.)
  • Depth: 99.5 cm (39.0 in.)

Mass range

  • 2 to 2048 m/z

Scan speed

  • Up to 10,000 Da/s
  • Examples of achievable acquisition rates:
  • 10 scans per second (m/z 50 to 1000)
  • 20 scans per second (m/z 50 to 500)

Linearity of response

  • The linearity of response relative to sample concentration, for a specified compound, is five orders of magnitude from the limit of detection

Switching time

  • 20 ms to switch between positive and negative ion modes
  • MS to MS/MS switching time 3 ms
  • ESCi mode switching time 20 ms to switch between ESI and APCI

MRM acquisition rate

  • Maximum acquisition rate of 250 MRM data points per second;
  • Minimum dwell time of 1 ms per MRM channel;
  • Minimum inter-channel delay of 3 ms

Inter-channel cross talk

  • The inter-channel cross talk between two MRM transitions, acquired using an MRM dwell time of 1 ms and an inter-channel delay time of 3 ms, is less than 0.01%
  • Number of MRM channels Up to 16,384 MRM channels (512 functions, 32 channels per function) can be monitored in a single acquisition; up to 8,000 MRM channels when operating in GLP/secure mode (250 functions, 32 channels per function)

MRM sensitivity (ESI+)

  • A 1 pg on-column injection of reserpine will give a chromatographic signal-to-noise greater than 300,000:1, using raw unsmoothed data (Gradient separation, LC mobile phase flow rate of 0.8 mL/min, MRM transition m/z 609 > 195)

MRM sensitivity (ESI-)

  • A 1 pg on-column injection of chloramphenicol will give a chromatographic signal-to-noise greater than 200,000:1, using raw unsmoothed data (Gradient separation, LC mobile phase flow rate of 0.8 mL/min, MRM transition m/z 321 > 152)

Detailed information

The system comes complete, including rotary pumps, data system and MassLynx operating software package.

MS Vision can optionally offer an interesting package deal including a (nano-)Acquity UHPLC system.

We deliver each pre-owned system including costs for delivery & insurance, paid, including installation on basis of the original specification of the instrument, hands-on training and warranty. We will continue supporting the system after the warranty period, a.o. via a range of service contract options.

 

SKU: WAA095 Category: Product specifications:   <p>Company: Waters<br /> Instrument type: Benchtop tandem quadrupole<br /> Instrument system: MS (Mass Spectrometer)</p> System features:   <p>Xevo® TQ-S is an advanced benchtop tandem quadrupole mass spectrometer, designed to meet the needs of your most demanding quantitative LC-MS/MS applications.</p> <p>Xevo TQ-S features revolutionary off-axis StepWave™ ion transfer optics that dramatically increases the efficiency of ion transfer from the ion source to the quadrupole MS analyzer at the same time as actively eliminating undesirable neutral contaminants.</p> <p>Xevo TQ-S also features ScanWave™ collision cell technology to provide the very best high-speed MRM, an enhanced product ion spectral acquisition capability and a valuable, information-rich acquisition mode known as RADAR.™ The system incorporates IntelliStart™ Technology, for automated system optimization and status monitoring, ensuring that the highest quality data is routinely available to all levels of operator.</p> <p>SYSTEM HARDWARE SPECIFICATIONS</p> <p>API sources and ionization modes High performance ZSpray™ dual-orthogonal API sources:</p> <ul> <li>Multi-mode source – ESI/APCI/ESCi®</li> </ul> <p>Vacuum system</p> <ul> <li>Three air-cooled turbomolecular vacuum pumps;</li> <li>Two vacuum backing pumps</li> </ul> <p>Dimensions</p> <ul> <li>Width: 61.0 cm (24.0 in.)</li> <li>Height: 70.7 cm (27.8 in.)</li> <li>Depth: 99.5 cm (39.0 in.)</li> </ul> <p>Mass range</p> <ul> <li>2 to 2048 <em>m/z</em></li> </ul> <p>Scan speed</p> <ul> <li>Up to 10,000 Da/s</li> <li>Examples of achievable acquisition rates:</li> <li>10 scans per second (<em>m/z </em>50 to 1000)</li> <li>20 scans per second (<em>m/z </em>50 to 500)</li> </ul> <p>Linearity of response</p> <ul> <li>The linearity of response relative to sample concentration, for a specified compound, is five orders of magnitude from the limit of detection</li> </ul> <p>Switching time</p> <ul> <li>20 ms to switch between positive and negative ion modes</li> <li>MS to MS/MS switching time 3 ms</li> <li>ESCi mode switching time 20 ms to switch between ESI and APCI</li> </ul> <p>MRM acquisition rate</p> <ul> <li>Maximum acquisition rate of 250 MRM data points per second;</li> <li>Minimum dwell time of 1 ms per MRM channel;</li> <li>Minimum inter-channel delay of 3 ms</li> </ul> <p>Inter-channel cross talk</p> <ul> <li>The inter-channel cross talk between two MRM transitions, acquired using an MRM dwell time of 1 ms and an inter-channel delay time of 3 ms, is less than 0.01%</li> <li>Number of MRM channels Up to 16,384 MRM channels (512 functions, 32 channels per function) can be monitored in a single acquisition; up to 8,000 MRM channels when operating in GLP/secure mode (250 functions, 32 channels per function)</li> </ul> <p>MRM sensitivity (ESI+)</p> <ul> <li>A 1 pg on-column injection of reserpine will give a chromatographic signal-to-noise greater than 300,000:1, using raw unsmoothed data (Gradient separation, LC mobile phase flow rate of 0.8 mL/min, MRM transition <em>m/z </em>609 > 195)</li> </ul> <p>MRM sensitivity (ESI-)</p> <ul> <li>A 1 pg on-column injection of chloramphenicol will give a chromatographic signal-to-noise greater than 200,000:1, using raw unsmoothed data (Gradient separation, LC mobile phase flow rate of 0.8 mL/min, MRM transition <em>m/z </em>321 > 152)</li> </ul> Detailed information:   <p><span lang="EN-GB">The system comes complete, including rotary pumps, data system and MassLynx operating software package.</span></p> <p><span lang="EN-GB">MS Vision can optionally offer an interesting package deal including a (nano-)Acquity UHPLC system.</span></p> <p><span lang="EN-GB">We deliver each pre-owned system including costs for delivery & insurance, paid, including installation on basis of the original specification of the instrument, hands-on training and warranty. We will continue supporting the system after the warranty period, a.o. via a range of service contract options. </span></p> <p> </p> Additional Information:   TQ-S, Waters, , , ,